Multiply needs to be 16 stages to fix all timing issues
This seems dependent on the FPGA type/size, so we should probably make it a toplevel generic, but for now this helps on the Arty A7-35 Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>pull/77/head