forked from cores/microwatt
You cannot select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
102 lines
2.9 KiB
VHDL
102 lines
2.9 KiB
VHDL
library ieee;
|
|
use ieee.std_logic_1164.all;
|
|
use ieee.numeric_std.all;
|
|
|
|
library work;
|
|
use work.common.all;
|
|
use work.decode_types.all;
|
|
|
|
entity multiply is
|
|
generic (
|
|
PIPELINE_DEPTH : natural := 16
|
|
);
|
|
port (
|
|
clk : in std_logic;
|
|
|
|
m_in : in Execute1ToMultiplyType;
|
|
m_out : out MultiplyToExecute1Type
|
|
);
|
|
end entity multiply;
|
|
|
|
architecture behaviour of multiply is
|
|
signal m: Execute1ToMultiplyType;
|
|
|
|
type multiply_pipeline_stage is record
|
|
valid : std_ulogic;
|
|
insn_type : insn_type_t;
|
|
data : signed(129 downto 0);
|
|
is_32bit : std_ulogic;
|
|
end record;
|
|
constant MultiplyPipelineStageInit : multiply_pipeline_stage := (valid => '0',
|
|
insn_type => OP_ILLEGAL,
|
|
is_32bit => '0',
|
|
data => (others => '0'));
|
|
|
|
type multiply_pipeline_type is array(0 to PIPELINE_DEPTH-1) of multiply_pipeline_stage;
|
|
constant MultiplyPipelineInit : multiply_pipeline_type := (others => MultiplyPipelineStageInit);
|
|
|
|
type reg_type is record
|
|
multiply_pipeline : multiply_pipeline_type;
|
|
end record;
|
|
|
|
signal r, rin : reg_type := (multiply_pipeline => MultiplyPipelineInit);
|
|
begin
|
|
multiply_0: process(clk)
|
|
begin
|
|
if rising_edge(clk) then
|
|
m <= m_in;
|
|
r <= rin;
|
|
end if;
|
|
end process;
|
|
|
|
multiply_1: process(all)
|
|
variable v : reg_type;
|
|
variable d : std_ulogic_vector(129 downto 0);
|
|
variable d2 : std_ulogic_vector(63 downto 0);
|
|
variable ov : std_ulogic;
|
|
begin
|
|
v := r;
|
|
|
|
m_out <= MultiplyToExecute1Init;
|
|
|
|
v.multiply_pipeline(0).valid := m.valid;
|
|
v.multiply_pipeline(0).insn_type := m.insn_type;
|
|
v.multiply_pipeline(0).data := signed(m.data1) * signed(m.data2);
|
|
v.multiply_pipeline(0).is_32bit := m.is_32bit;
|
|
|
|
loop_0: for i in 1 to PIPELINE_DEPTH-1 loop
|
|
v.multiply_pipeline(i) := r.multiply_pipeline(i-1);
|
|
end loop;
|
|
|
|
d := std_ulogic_vector(v.multiply_pipeline(PIPELINE_DEPTH-1).data);
|
|
ov := '0';
|
|
|
|
-- TODO: Handle overflows
|
|
case_0: case v.multiply_pipeline(PIPELINE_DEPTH-1).insn_type is
|
|
when OP_MUL_L64 =>
|
|
d2 := d(63 downto 0);
|
|
if v.multiply_pipeline(PIPELINE_DEPTH-1).is_32bit = '1' then
|
|
ov := (or d(63 downto 31)) and not (and d(63 downto 31));
|
|
else
|
|
ov := (or d(127 downto 63)) and not (and d(127 downto 63));
|
|
end if;
|
|
when OP_MUL_H32 =>
|
|
d2 := d(63 downto 32) & d(63 downto 32);
|
|
when OP_MUL_H64 =>
|
|
d2 := d(127 downto 64);
|
|
when others =>
|
|
--report "Illegal insn type in multiplier";
|
|
d2 := (others => '0');
|
|
end case;
|
|
|
|
m_out.write_reg_data <= d2;
|
|
m_out.overflow <= ov;
|
|
|
|
if v.multiply_pipeline(PIPELINE_DEPTH-1).valid = '1' then
|
|
m_out.valid <= '1';
|
|
end if;
|
|
|
|
rin <= v;
|
|
end process;
|
|