library ieee;
|
|
use ieee.std_logic_1164.all;
|
|
use ieee.numeric_std.all;
|
|
|
|
library work;
|
|
use work.common.all;
|
|
|
|
entity register_file is
|
|
generic (
|
|
SIM : boolean := false
|
|
);
|
|
port(
|
|
clk : in std_logic;
|
|
|
|
d_in : in Decode2ToRegisterFileType;
|
|
d_out : out RegisterFileToDecode2Type;
|
|
|
|
w_in : in WritebackToRegisterFileType;
|
|
|
|
-- debug
|
|
sim_dump : in std_ulogic
|
|
);
|
|
end entity register_file;
|
|
|
|
architecture behaviour of register_file is
|
|
type regfile is array(0 to 31) of std_ulogic_vector(63 downto 0);
|
|
signal registers : regfile := (others => (others => '0'));
|
|
begin
|
|
-- synchronous writes
|
|
register_write_0: process(clk)
|
|
begin
|
|
if rising_edge(clk) then
|
|
if w_in.write_enable = '1' then
|
|
assert not(is_x(w_in.write_data)) and not(is_x(w_in.write_reg)) severity failure;
|
|
report "Writing GPR " & to_hstring(w_in.write_reg) & " " & to_hstring(w_in.write_data);
|
|
registers(to_integer(unsigned(w_in.write_reg))) <= w_in.write_data;
|
|
end if;
|
|
end if;
|
|
end process register_write_0;
|
|
|
|
-- asynchronous reads
|
|
register_read_0: process(all)
|
|
begin
|
|
if d_in.read1_enable = '1' then
|
|
report "Reading GPR " & to_hstring(d_in.read1_reg) & " " & to_hstring(registers(to_integer(unsigned(d_in.read1_reg))));
|
|
end if;
|
|
if d_in.read2_enable = '1' then
|
|
report "Reading GPR " & to_hstring(d_in.read2_reg) & " " & to_hstring(registers(to_integer(unsigned(d_in.read2_reg))));
|
|
end if;
|
|
if d_in.read3_enable = '1' then
|
|
report "Reading GPR " & to_hstring(d_in.read3_reg) & " " & to_hstring(registers(to_integer(unsigned(d_in.read3_reg))));
|
|
end if;
|
|
d_out.read1_data <= registers(to_integer(unsigned(d_in.read1_reg)));
|
|
d_out.read2_data <= registers(to_integer(unsigned(d_in.read2_reg)));
|
|
d_out.read3_data <= registers(to_integer(unsigned(d_in.read3_reg)));
|
|
|
|
-- Forward any written data
|
|
if w_in.write_enable = '1' then
|
|
if d_in.read1_reg = w_in.write_reg then
|
|
d_out.read1_data <= w_in.write_data;
|
|
end if;
|
|
if d_in.read2_reg = w_in.write_reg then
|
|
d_out.read2_data <= w_in.write_data;
|
|
end if;
|
|
if d_in.read3_reg = w_in.write_reg then
|
|
d_out.read3_data <= w_in.write_data;
|
|
end if;
|
|
end if;
|
|
end process register_read_0;
|
|
|
|
-- Dump registers if core terminates
|
|
sim_dump_test: if SIM generate
|
|
dump_registers: process(all)
|
|
begin
|
|
if sim_dump = '1' then
|
|
loop_0: for i in 0 to 31 loop
|
|
report "REG " & to_hstring(registers(i));
|
|
end loop loop_0;
|
|
assert false report "end of test" severity failure;
|
|
end if;
|
|
end process;
|
|
end generate;
|
|
|
|
end architecture behaviour;
|